Previous Page
Next Page
Testing Index On-Line Catalog
Catalog - Page 39

  • Fully automated precise testing combined with -73 degree to +190 degree Thermal Chamber
  • User programmable test procedures and thermal variation profiles via script engine
  • Measures over 100 different alternator parameters plus user customizable data points
  • User configurable Pass and Fail printed reports via MS Excel based report generator for virtually unlimited flexibility, includes performance curve, oscilloscope patter, test results and much more
  • Performance measure at variable temperatures with programmable delays Smart Delays can activate the next test cycle when a specified temperature is achieved
  • Checks all types of alternator and voltage regulator terminals and functions such as computer control, soft start delay, soft start protection, feedback, under/over voltage indication, PCM control, remote voltage control, load response control, tachometer frequency and more
  • Simulates all signals to the alternator including on-board computer function
  • Measures turn on speed, ripple current, stator balance, pulley size, input power, voltage regulator instability, stator voltage, reverse diode leakage, can test rectifier voltage drop, regulator saturation voltage, and (optional) torque & efficiency
  • 15-40 HP computer controlled variable speed motor with high reliability motor drive system
  • Computer controlled 300 (600 to 900 optional) Amp load bank with constant current or constant voltage modes
  • Built in battery simulator 12-32V for consistent test conditions
  • Fast Cooling via Liquid Nitrogen system, optional heating system is available
  • Database program for creation and editing of test conditions and the display of test result.  any statistics from previous test result can be retrieved for display
  • User configurable test procedures with Expandable measuring interface for custom requirements.  Eight insulated temperature inputs, eight auxiliary analog channels and eight auxiliary digital I/O available for customer defined measurements
  • Includes universal harness and regulator test plugs for popular applications
  • Built-in calibration, automatic diagnostic, manual, and detailed report test modes
  • Available in many working voltages (220 to 480V at 50/60 Hz).
Technical Data Measured Parameters:
•    Output voltage:  up to 50 Volts
•    Stator voltage:  up to 50 Volts
•    Output current:  up to 300 (600 to 900 optional) Amps
•    Field current:  up to 10 Amps
•    Alternator speed:  up to 12,000 (20,000 optional) RPM 
•    Alternator leakage:  up to 100 mA
•    Feedback voltage    0-50V (0-100% PWM)
•    Output power    0-10000W
•    Memory for unlimited part number profiles
•    Alternator temperature:  -73 to + 200 degrees C

Previous Page Next Page
Testing Index On-Line Catalog